ORIC — Grand Asian University ORIC Office of Research, Innovation & Commercialization

Mr. Usman Akram

Home Faculty Mr. Usman Akram

Biography will be available soon.

  • CT Scan, MRI, Ultrasonography, Echocardiography and Nuclear Imaging

  • Physiology, Radiation Science and Technology, General Radiology

  • <b>Radiologist-AI Double Reading for Incidental Oncology Findings: Detecting Overlooked Metastatic Clues in Routine Chest and Abdomen CT</b> Volume: 4 Pages: 1-12 Year: 0 Publisher: Link Medical Institute Type: National D O I: 10.61919/p8f43057 Paper Type: Article Abstract: Background: Routine contrast-enhanced chest and abdomen CT examinations performed for non-oncologic indications may contain subtle incidental oncologic findings that are missed or insufficiently emphasized during focused reporting. Objective: To evaluate whether a radiologist–AI double-reading quality assurance pathway can identify overlooked incidental oncologic findings on routine non-oncology CT and determine their clinical significance. Methods: This retrospective clinical correlation study included 2,486 eligible contrast-enhanced chest, abdomen, or combined chest–abdomen CT examinations from 3,214 retrieved studies at a tertiary-care hospital in Islamabad, Pakistan. De-identified scans were screened using a sensitivity-oriented AI triage system for suspicious skeletal, nodal, and visceral abnormalities. AI-flagged examinations underwent independent radiologist re-review, consensus adjudication, comparison with initial reports, and clinical validation through histopathology, follow-up imaging progression, or strong clinic-oncologic correlation. Results: AI flagged 412 of 2,486 examinations (16.6%). Radiologist re-review confirmed suspicious incidental oncologic findings in 187 flagged cases (45.4%). Of these, 56 cases (29.9%) were discordant with the initial report, representing 2.3% of the total cohort. Skeletal lesions were the most frequent overlooked abnormality (24/56; 42.9%), followed by nodal disease (17/56; 30.4%) and visceral lesions (15/56; 26.8%). Clinical validation confirmed malignancy-related disease in 38 of 56 discordant cases (67.9%). Conclusion: A radiologist–AI double-reading pathway selectively identified clinically meaningful overlooked oncologic findings while limiting secondary review to a minority of routine CT examinations. Keywords: Artificial intelligence; computed tomography; incidental findings; metastasis; radiology quality assurance; double reading; oncology. Journal Name: Journal of Health, Wellness and Community Research Issue No: 10 Published: 19-May-2026 Complete Citation: Usman Akram, Ahmad Waqar, Ayesha Waheed, Amna Abbas, Fareeha F Khan, Shaikh Khalid Muhammad (2026). <b>Radiologist-AI Double Reading for Incidental Oncology Findings: Detecting Overlooked Metastatic Clues in Routine Chest and Abdomen CT</b>. Journal of Health, Wellness and Community Research, 4(10), 1-12. https://doi.org/10.61919/p8f43057
  • COMPARISON OF DIGITAL RADIOGRAPHIC METHODS FOR EARLY DETECTION OF INTERPROXIMAL CARIES IN YOUNG ADULTS: A CROSS-SECTIONAL STUDY Volume: 3 Pages: 94-100 Year: 0 Publisher: Health and Research Insights Type: National D O I: 10.71000/dytg3h49 Paper Type: Article Abstract: Background: Early detection of interproximal enamel caries is a critical component of preventive dentistry, particularly in young adults where lesions often remain non-cavitated and clinically undetectable. Radiographic examination plays a central role in identifying these lesions; however, advances in digital imaging have introduced multiple radiographic techniques with varying diagnostic capabilities. Clear evidence comparing the diagnostic performance of these techniques for early enamel caries remains limited. Objective: To compare the sensitivity and specificity of three digital radiographic techniques for the detection of early interproximal enamel caries in young adults. Methods: A cross-sectional study was conducted among young adults attending dental clinics in an urban region. Standardized bitewing radiographs were obtained using direct digital sensor imaging, photostimulable phosphor plate imaging, and digitally enhanced radiography. Interproximal surfaces of posterior teeth were independently assessed by calibrated examiners blinded to clinical findings. Diagnostic outcomes were evaluated using sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy. Statistical comparisons were performed using parametric tests, with significance set at p < 0.05. Results: Early enamel caries were identified in 38.1% of the evaluated interproximal surfaces. Enhanced digital radiography demonstrated the highest sensitivity (81.4%) and overall diagnostic accuracy (79.8%). Direct digital sensor imaging showed moderate sensitivity (72.5%) and specificity (78.1%). Photostimulable phosphor plate imaging exhibited the highest specificity (82.4%) but lower sensitivity (65.3%). Differences in diagnostic performance among the three techniques were statistically significant. Conclusion: Digital radiographic techniques differed significantly in their ability to detect early interproximal enamel caries. Enhanced digital radiography improved lesion detection, whereas PSP plate imaging minimized false-positive findings. These results support the informed selection of radiographic methods to optimize early caries diagnosis and preventive care. Keywords: Dental Caries; Diagnostic Imaging; Early Diagnosis; Radiography, Dental; Sensitivity and Specificity; Young Adult Journal Name: Insights-Journal of Life and Social Sciences Issue No: 12 Published: 15-Dec-2025 Complete Citation: Saghir A, Ali Asmar Meer, Saher Ahmed, Fatima Chaudhary, Usman Akram, Zainab Hayat (2025). COMPARISON OF DIGITAL RADIOGRAPHIC METHODS FOR EARLY DETECTION OF INTERPROXIMAL CARIES IN YOUNG ADULTS: A CROSS-SECTIONAL STUDY. Insights-Journal of Life and Social Sciences, 3(12), 94-100. https://doi.org/10.71000/dytg3h49
  • APPLICATION OF ARTIFICIAL INTELLIGENCE IN DETECTING MUSCULOSKELETAL ABNORMALITIES THROUGH AUTOMATED RADIOGRAPHIC IMAGE ANALYSIS: SYSTEMATIC REVIEW Volume: 3 Pages: 162-167 Year: 0 Publisher: Health and Research Insights Type: National D O I: 10.71000/t761gz19 Paper Type: Article Abstract: Background: Artificial intelligence (AI) is rapidly transforming diagnostic radiology, particularly in musculoskeletal imaging where precise and timely detection of abnormalities is essential for effective treatment. While numerous AI applications have been explored in individual studies, the lack of a consolidated synthesis of their diagnostic accuracy and clinical relevance in radiographic analysis of musculoskeletal disorders highlights a significant gap in the literature. Objective: This systematic review aims to evaluate the current evidence on the application of artificial intelligence in detecting musculoskeletal abnormalities using automated analysis of radiographic images, focusing on diagnostic accuracy, clinical utility, and limitations. Methods: A systematic review was conducted in accordance with PRISMA guidelines. Databases including PubMed, Scopus, Web of Science, and Cochrane Library were searched for studies published between 2018 and 2025. Eligible studies involved human subjects, applied AI to musculoskeletal radiographic imaging, and reported diagnostic outcomes. Data were extracted on study design, AI algorithms, sample size, outcomes, and performance metrics. Risk of bias was assessed using QUADAS-2 and Newcastle-Ottawa Scale tools based on study type. Results: Eight studies were included, encompassing diagnostic accuracy studies, narrative reviews, and one systematic review. AI models demonstrated high diagnostic performance, with AUC values ranging from 0.87 to >0.99, and strong correlation with expert radiologist interpretations. Applications included fracture detection, joint assessment, implant analysis, and TMJ osteoarthritis diagnosis. Variability in study designs and outcome reporting limited the feasibility of meta-analysis. Conclusion: AI demonstrates significant potential in improving the accuracy and efficiency of musculoskeletal radiographic interpretation. However, heterogeneity across studies and limited external validation underscore the need for further prospective, real-world research to support clinical integration and ensure generalizability. Keywords: Artificial Intelligence, Musculoskeletal Disorders, Radiographic Imaging, Deep Learning, Diagnostic Accuracy, Systematic Review Journal Name: Insights-Journal of Life and Social Sciences Issue No: 4 (Social) Published: 18-Aug-2025 Complete Citation: Mughal S, Muhammad Naveed babur, Zohaib shahid, Muhammad Munhib Shehzad, Rao Rubina, Usman Akram (2025). APPLICATION OF ARTIFICIAL INTELLIGENCE IN DETECTING MUSCULOSKELETAL ABNORMALITIES THROUGH AUTOMATED RADIOGRAPHIC IMAGE ANALYSIS: SYSTEMATIC REVIEW. Insights-Journal of Life and Social Sciences, 3(4 (Social)), 162-167. https://doi.org/10.71000/t761gz19
  • ARTIFICIAL INTELLIGENCE–BASED MRI RADIOMICS FOR EARLY PREDICTION OF ISCHEMIC STROKE OUTCOMES Volume: 4 Pages: 13 Year: 0 Type: National Paper Type: Article Abstract: Objective: This study aims to develop an AI-based radiomics model using MRI data to predict early functional outcomes in ischemic stroke patients. It evaluates the predictive accuracy of imaging-derived features compared with conventional clinical predictors. The research seeks to enhance early prognostic decision-making in stroke care. Method: This retrospective analytical study was conducted at a tertiary hospital in Punjab, Pakistan. The study included ischemic stroke patients who underwent MRI within 24 hours of symptom onset. Radiomic features were extracted from the MRI images, and a machine learning model was trained to predict early outcomes, specifically focusing on functional independence (as measured by the modified Rankin Scale, mRS). The model's performance was compared to that of clinical predictors, including National Institutes of Health Stroke Scale (NIHSS) scores and age. Results: The AI-based radiomics model demonstrated superior predictive accuracy compared to clinical predictors. The area under the receiver operating characteristic curve (AUC) for the radiomics model was 0.86, significantly higher than the AUC of 0.72 for clinical predictors alone. The radiomics features, such as lesion volume and texture heterogeneity, were identified as key indicators of functional outcomes. Additionally, integrating AI-derived MRI features with clinical predictors improved the model’s sensitivity and specificity. Keywords: ISCHEMIC STROKE OUTCOMES, RADIOMICS Journal Name: Frontier in medical Health Researh Issue No: 1

  • Internship Grade: A Year: 2023 Institution: National Hospital Faislabad Field Of Study: Radiography Type: Certificate

  • Riphah International University Faisalabad Designation: Demonstrator Role: Deliver Lectures From: 18-Feb-25 To: 30-Jun-25 Type: Teaching

More from Department of Allied Health Sciences

Have a Research Idea or Proposal?

Partner with ORIC to turn your research into innovation and impact. We support you at every step — from proposal to commercialization.

Get In Touch